Responsible for around 40% of the total energy consumption in Europe, construction is one of the priority areas in the decarbonisation strategy promoted by European legislation. In this scenario, the building envelope • the •skin of the building • assumes a strategic role, since it directly affects the building's ability to retain heat, regulate the internal microclimate and reduce energy requirements. Nearly Zero Energy Buildings (nZEB) offer a well-established reference point for energy efficiency, the recent regulatory evolution has introduced an even more ambitious standard: that of zero emission buildings (ZEmB).

What does it mean to build a nZEB building: definition and regulatory framework The term nZEB (Nearly Zero Energy Building) has been introduced at European level with the Directive 2010/31/EU, and identifies buildings with a very high energy performance**, whose energy needs are very low and largely covered by renewable sources. The aim of this design approach is to reduce consumption through a set of ** passive strategies, plant technologies** evolved and intelligent use of natural resources, while ensuring high standards of living comfort. In the last decade, the concept of nZEB has marked a crucial shift towards the energy transition of the European building heritage. However, with the acceleration of the climate crisis and the adoption of the package Fit for 55 and Green Deal EuropeanThe need to set even more ambitious targets emerged, hence the latest revision of the legislation on the subject: the EPBD IV • Energy Performance of Buildings Directive, which introduces the new generation of EmB buildings (Zero Emission Buildings). Unlike nZEB, which aims to minimize energy consumption, ZEmB aims to set off CO2 emissions, covering the entire energy needs with renewable sources produced on site and also assessing the environmental impact throughout the entire life cycle of the building, from materials used to the phase of use and maintenance. We are therefore faced with a paradigm jump that makes even more evident the active role of building in the fight against climate change**.

The horizon set by the European Union is clear: from 2030 all new buildings will have to be zero emissions, with an anticipation of 2027 for public buildings. The final objective, planned for 2050, remains that of the complete decarbonisation of the building heritage. The containment of energy needs therefore becomes an indispensable design priority, to be realized also and above all through a ** performing building envelope**, which maximizes passive efficiency and reduces dependence on plant systems.

The building envelope: the great ally of energy efficiency The building envelope is the set of physical components that separate the interior of a building from the exterior environment: vertical matt walls, horizontal or inclined covers, only to non-climatic spaces and transparent surfaces such as windows, doors and windows. It is, in other words, **the

Its function is anything but passive: the shell has a decisive effect on the regulation of the internal microclimate, contributing to the maintenance of a comfortable temperature in all seasons and to the reduction of energy requirements for heating and cooling. In summary, a well-designed enclosure heat island environments, limits infiltration air, controls humidity and optimizes the natural light supply. In a ** nZEB** building, the shell is conceived from the design stage as an active element of efficiency**. Thanks to a careful selection of insulating materials, the reduction of thermal bridges and the adoption of innovative construction systems, it contributes significantly to the energy balance of the building, allowing to reduce the dispersions and optimize the overall performance. It is not only a matter of building better, but of rethinking the interaction between building and environment, transforming the shell from simple passive protection to a tool for saving and sustainability.

Design strategies for the efficiency of the shell in nZEB buildings Realising a nZEB building means acting in a targeted way on each component of the shell to minimize energy losses and maximize passive efficiency.At the end, some of the main design strategies to optimize the shell and contribute to the achievement of the required energy standards.

Thermal insulation: materials and technologies The insulation of the enclosure is essential to contain energy needs. high-performance insulating materials, such as mineral wool, expanded polystyrene and innovative aerogel-based panels, allow to limit thermal transmission and improve the overall efficiency of the building. One of the most widespread solutions in nZEB is the Coat system, which involves the laying of insulating layers outside the matt vertical structures in order to significantly reduce thermal bridges and protect the masonry from thermal excursions. In some contexts, however, the outer insulation may not be practicable (architectural or condominium boundaries): in these cases, solutions of internal isolation are used, less effective in terms of continuity, but nevertheless useful in improving the performance of the enclosure.

High-performance locks The transparent surfaces are among the critical points of the enclosure because they can favor heat dispersion in winter and overheating in summer. It is therefore essential to choose high performance locks, equipped with low emissive, double or triple glass, which can contain the thermal transmittance without sacrificing natural light. The fixtures must also be made with thermal cut profiles, which interrupt the continuity of the conductive material (usually metal), reducing energy losses. However, even the best windowing loses much of its effectiveness if it is not installed correctly: the laying must therefore be performed with techniques that guarantee the continuity of the insulation and the absence of thermal bridges** between the frame and the masonry.

Ventilated facades and multifunctional walls Another effective design strategy to increase the efficiency of the building envelope is The use of ventilated facades. This system provides an air layer between the matt wall and the outer coating, which allows the natural ventilation and reduces the accumulation of heat during the summer months. In addition to containing the summer heat load, the ventilated facades also contribute to improve the durability of the building thanks to the protection from atmospheric agents and the reduction of surface condensation. In nZEB buildings, this type of wall can be associated with multifunctional materials, i.e. capable of simultaneously performing insulating, structural and regulating functions of the internal microclimate.

Solar factor control and shielding The management of the solar factor** • the amount of solar energy penetrating through the glass surfaces • is a crucial element to ensure summer comfort and avoid excessive use of air conditioning. In nZEB buildings, it is essential to find a balance between natural lighting and direct radiation control. Among the most effective solutions are the sunscreen, fixed or mobile, which allow to modulate light according to the season and the orientation of the building. These are flanked by ** solar controlled glazing**, which reflect part of the solar thermal energy while allowing visible light to pass through. The lens is dual: on the one hand limit the summer heat, on the other hand make the most of winter passive heating, reducing the use of the plants and improving overall energy efficiency.

Integrated design: air-tightness and mechanical ventilation In ** buildings nZEB**, the casing becomes an integral part of a building-plant system designed in a synergistic way.In this perspective, two aspects are central: the ** air-tightness** of the casing and the adoption of ** controlled mechanical ventilation systems** (VMC) with heat recovery. Ensuring high air-tightness means eliminating unwanted air infiltration of external air, responsible for thermal dispersions, cold currents and housing discomforts. In high-performance projects, each point of discontinuity The system efficiency. A ** housing • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • A reference model in this area is the Passive House, the construction standard born in Germany and today wide spread. The requirements of this protocol (including an airtight airtight n50 ≤ 0.6/h and a heat load ≤ 10 W/m2) show how a well-designed enclosure, combined with efficient mechanical ventilation, can ensure high levels of comfort with minimal consumption. In addition, a performance and correct ventilation shell are crucial for the wellness indoor, i.e. air quality, relative humidity, surface temperature of the walls and no currents: all parameters affecting the health and perception of comfort of the occupants. Designing airtightness and ventilation as part of a single integrated strategy means that they are healthier, more efficient and smarter buildings.

Sustainable materials for building enclosures EPBD IV Directive, which extends the focus from operating energy performance alone to the whole life cycle of the building** (LCA •Life Cycle AssessmentIn this context, the design of the enclosure must take into account not only the thermal and mechanical characteristics of the materials, but also their overall environmental impact**: from raw materials extraction to production, transport to disposal, through the use phase. incorporated low-emission materials (embodied carbon) is a strategic choice today. Increasingly common are the materials recycled, biocompatible or negative carbon, that is, capable of absorbing more CO2 than they release during their entire useful life. The use of solutions with reduced environmental impact allows to break down the carbon footprint of the shell, contributing in a concrete way to the European goals of climate neutrality.

Involve existing buildings with energy retrofit Finally, the process of transition to nZEB buildings cannot be without an incisive action on the existing building heritageThe energy reduction retrofit, which in Italy is largely the result of an energy obsolete**, is the result of the production of energy efficiency improvements in a pre-existing building, which reduces energy consumption and greenhouse gas emissions. In this context, the improvement of the enclosure is one of the most effective interventions to increase the energy class of buildings**. Acting on walls, roofing and windows allows to reduce thermal dispersions, to reduce consumption and to make the building more performing even without distorting the structure or the plants. Operations such as the application of outer coats, the replacement of fixtures or the insulation of roofs can significantly increase the efficiency of the building, with immediate effects on comfort and bills. To support these operations, the incentivising tools The tax deductions are essential: tax deductions such as l'[** Ecobonus** and Superbonus (in the versions still available and in annual update) allow access to important facilities for those investing in energy efficiency. An additional advantage of retrofit on the shell is the possibility of resorting to uninvasive solutions, able to adapt to the specifics of the building without compromising the functionality or aesthetics. Low-thick insulating systems, light ventilated facades or prefabricated internal counter walls offer valid alternatives in the bound environments or in the condominiums, where the works must ensure fast timing and low impacts.

To view videos, enable external content in your cookie preferences.